One MV SMPs fits directly onto the front of each MV DELTA Transistor Bridge Module.Proceed to fit the SiMps unit after the transistor module is installed in the enclosure as follows:
Fit all power cabling to the DELTA Transistor Bridge before fitting the SMps unitab)Loosely fix the two i5 pozi-head fixing screws (with captive spring washer) to the upper face of themodule as shown in Figure 1
Mount the SMps unit onto the two M5 fixing screws on the DELTA Transistor Bridge and fully tighten thescrews
Remove the blanking plug from TB1 on the front of the DELTA Transistor Bridge and connect the DCcable assembly to TB1
Connect the 40 way ribbon cable from Pl3 on the DELTA Transistor Bridge to PL2 on the SMps daughterboard,20X4344
One MV SMPs fits directly onto the front of each MV DELTA Transistor Bridge Module.
Proceed to fit the Sips unit after the transistor module is installed in the enclosure as follows:
司
Fit all power cabling to the DELTA Transistor Bridge before fitting the SPs unit (to gain access to allterminals,
Remove the back plate from the DELTA Transistor Bridge by loosening all M5 fixings and lifting off)
Refit the back plate
Mount the SiMPs unit, using the three locating tabs and secure with three M5 Nyloc nuts (supplied withthe Transistor Bridge) onto the M5 studs
Note: For MVC3003-40258 & MVC3003-4030B, which have a flat mounting bracket, if bump stops arefitted to the transistor module back plate, these will need to be removed before fitting the SiPs unitRemove the blanking plug from TB1 on the front of the DELTA Transistor Bridge and connect the DCcable assembly to TB1
Connect the 40 way ribbon cable from Pl3 on the DElTA Transistor Bridge to PL2 on the SMps daughterboard,20X4344.